This fully automated clinical imaging analyzer is designed for rapid and highly accurate quantification of CD34+ hematopoietic stem and progenitor cells prior to transplantation. Using advanced fluorescent imaging technology calibrated to ISHAGE guidelines, it delivers flow-cytometry–comparable results without the need for complex gating, washing steps, or expert operation. With an All-in-One reagent system, automated multi-field image acquisition, and real-time result delivery, the system significantly shortens decision-making time in blood banks and transplant centers while improving accuracy, reproducibility, and operational efficiency.

Please Log In to access Additional Details and documents …

  • Automated CD34+ cell quantification:
    Fully automated enumeration of CD34+, CD45+, and viable cell populations with automated capture of 75 image fields per sample for high statistical accuracy.

  • ISHAGE-calibrated workflow:
    Factory calibration according to ISHAGE guidelines eliminates the need for manual gating, calculations, or expert adjustments.

  • All-in-One reagent system:
    Single reagent set contains CD34, CD45, viability dye, and RBC lysis buffer, removing washing steps and reducing hands-on time and error risk.

  • High-speed analysis for rapid decision-making:
    Each analysis is completed within minutes, providing immediate feedback on stem cell graft quality.

  • Broad transplant-related sample compatibility:
    Supports HPC-A, mobilized peripheral blood, and cord blood samples with a required volume of only 25 µL.

  • Multichannel fluorescent imaging system:
    Optical system with 1 bright-field and 3 fluorescence channels using a high-sensitivity monochrome CCD camera.

  • Minimal maintenance requirements:
    No washing, buffers, cleaning cycles, warm-up, or stabilization time required.

  • Comprehensive measurement outputs:
    Total CD34+, viable CD34+, total CD45+, cell viability percentage, population ratios, and absolute counts per µL.

  • Simple single-slide workflow:
    Incubate sample with reagent, add RBC lysis buffer, load onto assay slide, insert slide, and start measurement.

  • Clinical deployment areas:
    Blood banks, stem cell transplantation centers, and clinical laboratories requiring fast and standardized graft assessment.

  • Regulatory compliance:
    Certified for clinical use with FDA 510(k) and CE IVD approvals.

  • Compact benchtop design:
    Dimensions 300 × 420 × 370 mm; weight approximately 19.3 kg.